Case 1: iVue GCC Thickness Patient vs. Normal Comparison OU April 2011


The patient’s GCC Thickness Map is
shown to the left and a normal control
is shown below tor comparison. The
normal control reveals a typical “green
donut” in each eye which corresponds
to the thickness of GCC. The thin
center, which represents the fovea, is
normally devoid of ganglion cells. The
color scale demonstrates that the GCC
is nearly 100 microns in thickness in
each eye in this normal patient. In
contrast, note that the patient in Case
1 has a GCC which is quite reduced in
thickness, more marked in the left eye.